1948312A1 N-Type Female to N-Type Female Adapter
6634408A4 Serial Cable; 1 Ft; used for connecting NIAI02 to NIAM02 and other NIAI02; used for cold junction compensation of TC inputs
NKAI01 Cold Junction Compensation Cable; used to connect NTAI02 to NTAM01 and other NTAI02
NKAI11 Cold Junction Compensation Cable; used to connect NTAI02 to NTAM01 and other NTAI02
NKAL01 External Alarm Cable for PCU
NKAS01 Analog Module to Termination Unit Cable; used to connect IMASI03 to NTAI06
NKAS02 Termination Module Cable; used to connect IMASI03 to (2) NTAI05
NKAS11 Analog Slave Termination Unit Cable; used to connect IMASI03 to NTAI06
NKAS12 Termination Module Cable; used to connect IMASI03 to (2) NTAI05
NKCL01 "Coaxial Infinet/RIO Communication Link Cable; used to connect TCL/ICL to TCL/ICL, TRL/IRL to TRL/IRL; must use with NKTL01"
NKCL11 "Coaxial Infinet/RIO Communication Link Cable; used to connect TCL/ICL to TCL/ICL, TRL/IRL to TRL/IRL; must use with NKTL01"
NKCS01 "Analog Control Station Cable; used to connect termination unit to IISAC01, NDIS01; no daisychain"
NKCS02 "Analog Control Station Cable; used to connect termination unit to IISAC01, NDIS01; with series connect for daisychain"
NKCS11 "Analog Control Station Cable; used to connect termination to IISAC01, NDIS01; no daisychain"
NKCS12 "Analog Control Station Cable; used to connect termination unit to IIASC01, NDIS01; with series connect for daisychain"
NKDO01 Digital Output Cable; used to connect NTDO02 to NTDO02; used to provide 16 SS Relay outputs via IMDSO04
NKDO11 Digital Output Cable; used to connect NTDO02 to NTDO02; used to provide 16 SS Relay outputs via IMDSO04
NKDS03 "Analog Control Station Cable; used to connect IISAC01, NDIS01; with series connector on daisychain"
NKDS04 Digital Logic Station Cable; used to connect NTLS01 to NDLS02; with series connector for diasychain
NKDS05 Digital Logic Station Cable; used to connect NDLS02 to other NDLS02; with series connector for diasychain
NKDS13 "Analog Control Station Cable; used to connect IISAC01, NDIS01; with series connector on daisychain"
NKDS14 Digital Logic Station Cable; used to connect NTLS01 to NDLS02; with series connector for daisy chain
NKDS15 Digital Logic Station Cable; used to connect NDLS02 to other NDLS02; with series connector for diasychain
NKHS03 Hydraulic Servo Termination Calbe; used to connect IMHSS03 to NTHS03
NKHS13 Hydraulic Servo Termination Calbe; used to connect IMHSS03 to NTHS03
NKLM01 "Communication Interface Cable; used to connect IMRIO02 to NTRL02, NTRL03"
NKLM11 "Communication Interface Cable; used to connect IMRIO02 to NTRL02, NTRL03"
NKLS01 Infi-net Interface Cable; used to connect INNIS01 to NTCL01
NKLS02 Infi-net Interface Cable; used to connect INNIS01 to NICL01 ribbon cable
NKLS03 Plant Loop Interface Cable; used to connect INLIM03 to NTCL01
NKLS04 Plant Loop Interface Cable; used to connect INLIM03 to NICL01
NKLS11 Infi-net Interface Cable; used to connect INNIS01 to NTCL01
NKLS12 Infi-net Interface Cable; used to connect INNIS01 to NICL01 ribbon cable
NKLS13 Plant Loop Interface Cable; used to connect INLIM03 to NTCL01
NKLS14 Plant Loop Interface Cable; used to connect INLIM03 to NICL01
NKMC01 CRT RGB Cable; used to connect OIS to OIC
NKMF02 Multi-Function Cable; used to connect redundant IMAMM03 without DIS or TC Input
NKMP01 "Multi-Function Processor Cable; used to connect redundant IMMFP01/02 without Basic, C, or Stations"
NKMP03 Multi-Function Processor Cable; used to connect redundant IMMFP03
NKMR01 "CRT/Keyboard/Printer Serial Cable; used to connect OIS to OIC; used to connect OIS to IIPRT02,3,5"
NKPL01 Twinax Plant Loop Cable; used to connect NTCL01 to NTCL01; used to connect NTRL03 to NTRL03
NKPL11 Twinax Plant Loop Cable; used to connect NTCL01 to NTCL01; used to connect NTRL03 to NTRL03
NKSD01 80E Digital Input Module Cable; used to connect IMSED01 to NTDI01
NKSE01 Serial Extension Cable; used to connect NTCS04 to NTCS04 with analog/digital stations when using IMMFP0x
NKSE11 Serial Extension Cable; used to connect NTCS04 to NTCS04 with analog/digital stations when using IMMFP0x
NKSM01 Server Module Cable
NKST01 80E Time Synch Cable; used to connect IMSET01 to NTST01
NKTD01 Termination Station Cable; Y Cable; used to connect NIDS01 to two cables for analog/digital stations
NKTD02 Termination Station Cable; used to connect analog/digital station directly to NICS01; no bypass for IISAC01 on this link
NKTK01 Time Keeper Master Cable; used to connect INKTM01 to NTST01
NKTL01 "Coax Termination Cable; used to connect NKCL01 Coax cable to TRL01/NIRl01, NTCL01/NICL01; flame retardent"
NKTM01 I/O Module to Termination Module Ribbon Cable
NKTM02 I/O Module to Termination Module Cable
NKTT01 Infi-net Termination Cable; used to connect NTCL01/NICL01 to NTCL01/NICL01 which are close together
NKTU01 I/O Module to Termination Unit Cable
NKTU02 I/O Module to Termination Module Cable
NKTU11 I/O Module to Termination Unit Cable